Sprinklers » Residential » Residential Sprinklers
A-1 Pendent Sprinkler - GL4110/GL4910
Automatic Sprinklers Model GL4110 & GL4910 Pendent Recessed Pendent
Description and Operation
The Globe Model GL4110 and GL4910 Residential Sprinklers have a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. They feature economy, aesthetics and low flow.
The combination of the 3mm frangible glass ampule and specially designed deflector make the Model GL4110 and GL4910 Residential Sprinklers the ultimate in life safety and fire control. These Globe Pendent and Recessed Pendent Residential Sprinklers have met the strict requirements of Underwriters Laboratories Inc. as described in the UL Standard for Residential Sprinklers for Fire Protection Service, UL 1626, and should be used accordingly. These sprinklers should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authorities having jurisdiction.
The heart of Globe's Model GL4110 and GL4910 sprinklers proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.
Technical Data
- Temperature Rating - 155°F (68°C), 175°F (79°C)
- Water Working Pressure Rating - 175 psi (12 Bars)
- Factory tested hydrostatically to 500 psi (34 Bars)
- Maximum low temperature glass bulb rating is
-67°F (-55°C) - Frame - bronze
- Deflector - brass
- Screw - brass
- Bulb seat - copper
- Spring - nickel alloy
- Seal - teflon
- Bulb - glass with alcohol based solution, 3mm size
- Escutcheon Assembly - steel
Sprinkler Temperature Rating/Classification and Color Coding
| Classification | Available Sprinkler Temperatures | Bulb Color | N.F.P.A. Maximum Ceiling Temperature | ||
|---|---|---|---|---|---|
| Ordinary | 155°F | 68°C | Red | 100°F | 38°C |
| Intermediate | 175°F | 79°C | Yellow | 150°F | 66°C |
Specifications and Approvals
| Sin Model | K Factor | Thread Size | Length | Finishes | 155°F 68°C | 175°F 79°C3 | cULus | NYC-DOB MEA 101-92-E |
|---|---|---|---|---|---|---|---|---|
| GL4110 | 4.1 (58 metric) |
1/2" NPT | 2 1/2" (6.4 cm) | Factory Bronze 1Satin Chrome Bright Chrome White Polyester2 Black Polyester2 1Lead Coated |
• | • | • | • |
| GL4910 | 4.9(68 metric) |
Note:
- Metric conversions are approximate.
- 1Finishes available on special order.
- 2C-U.L. Listed Corrosion Resistant - Polyester must be specified on order.
- 3 175°F listed for up to 16' x 16' room size.
Cross Section

Installation Data
Pendent and Recessed Pendent
| Model | Maximum Area of Coverage | Minimum Water Discharge & Pressures Needed Per Sprinkler* |
|---|---|---|
| GL4110 | 12' x 12' | 11 G.P.M. - 7.2 P.S.I. |
| 14' x 14' | 12 G.P.M. - 8.6 P.S.I. | |
| 16' x 16' | 14 G.P.M. - 11.7 P.S.I. | |
| GL4910 | 12' x 12' | 13 G.P.M. - 7 P.S.I. |
| 14' x 14' | 14 G.P.M. - 8.2 P.S.I. | |
| 16' x 16' | 14 G.P.M. - 8.2 P.S.I. | |
| 18' x 18' | 18 G.P.M. - 13.5 P.S.I. | |
| 20' x 20' | 20 G.P.M. - 16.7 P.S.I. |
*When these sprinklers are used in NFPA 13 systems, a 0.1 design density minimum shall be utilized.
Ordering Information
When ordering please specify the following.
- Quantity
- Model Number
- Style
- Orifice
- Temperature
- Finishes desired
- Quantity - Wrenches - P/N 325390
- Quantity - Recessed Wrenches - P/N 325391
- Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)
Product Related Documents
Related Products
Globe Product Warranty
Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment.
For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List).
Bulletin: GL4110/GL4910 Last Revised: January 2009 Revision: 5