Sprinklers » Residential » Replacement Residential Sprinklers
RA-3 Low Flow Pendent Sprinkler - GL2810
Automatic Sprinklers Model GL2810 Low Flow Pendent Recessed Pendent
Description and Operation
The Globe Model GL2810 Low Flow Residential Sprinkler is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. It features both economy and aesthetics.
The combination of the 3mm frangible glass ampule and innovative deflector design make the Model GL2810 Low Flow Residential Sprinkler the ultimate in life safety and fire control. The Globe Pendent and Recessed Pendent Model GL2810 Low Flow Residential Sprinklers have met the strict requirements of Underwriters Laboratories Inc. as described in the UL Standard for Residential Sprinklers for Fire Protection Service, UL 1626, and should be used accordingly. These sprinklers should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authorities having jurisdiction.
The heart of Globe's Model GL2810 sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.
Technical Data
- Temperature Rating - 155°F (68°C), 175°F (79°C)
- Water Working Pressure Rating - 175 psi (12 Bars)
- Factory tested hydrostatically to 500 psi (34 Bars)
- Maximum low temperature glass bulb rating is
-67°F (-55°C) - Frame - bronze
- Deflector - brass
- Screw - brass
- Bulb seat - copper
- Spring - nickel alloy
- Seal - teflon
- Bulb - glass with alcohol based solution, 3mm size
- Escutcheon Assembly - steel
Sprinkler Temperature Rating/Classification and Color Coding
| Classification | Available Sprinkler Temperatures | Bulb Color | N.F.P.A. Maximum Ceiling Temperature | ||
|---|---|---|---|---|---|
| Ordinary | 155°F | 68°C | Red | 100°F | 38°C |
| Intermediate | 175°F | 79°C | Yellow | 150°F | 66°C |
Specifications and Approvals
| Sin Model | K Factor | Thread Size | Length | Finishes | 155°F 68°C | 175°F 79°C | cULus | NYC-DOB MEA 101-92-E |
|---|---|---|---|---|---|---|---|---|
| GL2810 | 2.8 (40 metric) |
1/2" NPT | 2 1/4" (5.7 cm) | Factory Bronze Satin Chrome1 Bright Chrome White Polyester2 Black Polyester2 Lead Coated1 |
• | • | • | • |
Note:
- Metric conversions are approximate.
- 1Finishes available on special order.
- 2Available as U.L. and C-U.L. listed corrosion resistant when specified on order.
Cross Sections
Installation Data
Pendent Sprinkler
| Model | Maximum Area of Coverage | Minimum Water Discharge & Pressures Needed* |
|
|---|---|---|---|
| Single Sprinkler | Two Sprinklers | ||
| GL2810 | 12' x 12' | 10 G.P.M. - 12.7 P.S.I. |
8 G.P.M. - 8.2 P.S.I. (EACH) |
| 14' x 14' | 10 G.P.M. - 12.7 P.S.I. | 8 G.P.M. - 8.2 P.S.I. (EACH) | |
| 16' x 16' | 11 G.P.M. - 15.4 P.S.I. | 11 G.P.M. - 15.4 P.S.I. (EACH) | |
| 18' x 18' | 13 G.P.M. - 21.6 P.S.I. | 13 G.P.M. - 21.6 P.S.I. (EACH) | |
| 20' x 20' | 16 G.P.M. - 32.7 P.S.I. | 16 G.P.M. - 32.7 P.S.I. (EACH) | |
*When these sprinklers are used in NFPA 13 systems, a 0.1 design density minimum shall be utilized.
Ordering Information
When ordering please specify the following.
- Quantity
- Model Number
- Style
- Orifice
- Temperature
- Finishes desired
- Quantity - Wrenches - P/N 325390
- Quantity - Recessed Wrenches - P/N 325391
- Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)
Product Related Documents
Related Products
Globe Product Warranty
Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment.
For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List).
Bulletin: GL2810 Last Revised: October 2003 Revision: 2