3/4" Pendent Sprinklers - Extended Coverage Standard Response | Series GL-ECOH Glass Bulb - 11.2 K-factor
Not all temperatures and configurations may carry all Listings and Approvals. See data sheet for conditions of specific Listings and Approvals.
temperature | 155, 175, 200, 286 |
approvals | cULus, NYC |
SIN | GL1113 |
wrench | 333010 |
Recessed Wrench | 333011 |
EXTENDED COVERAGE ORDINARY HAZARD AUTOMATIC SPRINKLERS GL1121 & GL1113 UPRIGHT PENDENT RECESSED PENDENT
GFS-255_20200317CM (.pdf)
Download
|
Sprinkler Globe Pendent GL ECOH QR Imp (.rfa) | Download |
Sprinkler Globe Pendent GL ECOH QR Metric (.rfa) | Download |
Sprinkler Globe Pendent GL ECOH SR Imp (.rfa) | Download |
Sprinkler Globe Pendent GL ECOH SR Metric (.rfa) | Download |
Sprinkler Globe Recessed Pendent GL ECOH QR Imp (.rfa) | Download |
Sprinkler Globe Recessed Pendent GL ECOH QR Metric (.rfa) | Download |
Sprinkler Globe Recessed Pendent GL ECOH SR Imp (.rfa) | Download |
Sprinkler Globe Recessed Pendent GL ECOH SR Metric (.rfa) | Download |
QUICK RESPONSE / ORDINARY HAZARD (14x14 or less)
Glass Bulb – 11.2 K-factor Upright, Pendent, and Recessed Pendent Sprinklers. Quick Response, Extended Coverage: Where quick response, extended coverage ordinary hazard sprinklers are specified they shall be of an all bronze frame construction with brass deflector. Sprinklers shall have a 3mm glass bulb thermally sensitive operating element, and rated for a working pressure of 175 psi. Sprinklers installed in areas without a finished ceiling shall be of a bronze/brass finish and shall be of an appropriate temperature classification for the hazard. Sprinklers installed under a finished ceiling shall be a pendent style sprinkler with an adjustable recessed escutcheon of the same specified finish. Sprinklers shall be UL listed. Quick response, extended coverage ordinary hazard sprinklers shall be of the Series GL-ECOH; as manufactured by Globe Fire Sprinkler Corporation.
Glass Bulb – 11.2 K-factor Upright, Pendent, and Recessed Pendent Sprinklers. Standard Response, Extended Coverage: Where standard response, extended coverage ordinary hazard sprinklers are specified they shall be of an all bronze frame construction with brass deflector. Sprinklers shall have a 3mm glass bulb thermally sensitive operating element, and rated for a working pressure of 175 psi. Sprinklers installed in areas without a finished ceiling shall be of a bronze/brass finish and shall be of an appropriate temperature classification for the hazard. Sprinklers installed under a finished ceiling shall be a pendent style sprinkler with an adjustable recessed escutcheon of the same specified finish. Sprinklers shall be UL listed. Standard response, extended coverage ordinary hazard sprinklers shall be of the Series GL-ECOH; as manufactured by Globe Fire Sprinkler Corporation.
WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov.