1/2" Residential Flat Plate Concealed Pendent Sprinkler - Life Safety | Series GL-RES/"INCH" Glass Bulb - 4.9 K-factor

Not all temperatures and configurations may carry all Listings and Approvals. See data sheet for conditions of specific Listings and Approvals.

FEATURES

temperature 155
approvals cULus
SIN GL4906
wrench 332765
Recessed Wrench 332765

TECHNICAL DATA SHEET

"THE INCH ®" RESIDENTIAL AUTOMATIC SPRINKLERS GL4906 ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT
GFS-360_20181008CM (.pdf)
Download

FREQUENTLY ASKED QUESTIONS

Issue: Can residential sprinklers be installed in ceilings with slopes greater than 2 and 12? Can residential sprinklers be installed under beams up to 14 inches down from the ceiling? Solution: Yes they can as long as the room is not greater than 600 sq.ft. in area and the maximum ceiling height is not greater than 24 Ft. in height. See the Globe residential sprinkler installation guide or NFPA 13D, 2013 Edition, Section 10.2.1 for more details.
The State of California's Safe Drinking Water and Toxic Enforcement Act of 1986 (Proposition 65) requires manufacturers and distributors to provide special warnings to consumers for products that contain certain chemicals. The list, which must be updated at least once a year, has grown to include approximately 900 chemicals. Examples of chemicals on the list: alcoholic beverages, lead, nickel, wood dust, and Diesel/gasoline engine exhaust. Globe Fire Sprinkler cares about our customers' safety and hopes the information provided in our Proposition 65 warnings assist with your purchasing decisions. The appropriate warning labels are required for all physical and internet sales.

AutoCAD & Revit Files

Concealed Sprinkler Revit Files (.zip) Download

Auto CAD Details

GL4906 DRAWING A-10.dwg (.dwg) Download

specifications

Glass Bulb – 4.9 K-factor Residential Flat Plate Concealed Sprinklers. Fast Response, Residential Flat Plate Concealed Pendent Sprinkler: Where fast response, low profile flat plate adjustable concealed pendent sprinklers are specified for Residential, Life Safety applications per NFPA 13, 13R, 13D they shall be of an all bronze frame construction with brass deflector. Sprinklers shall have a 3mm fast response glass bulb thermally sensitive operating element, and rated for a working pressure of 175 psi. Sprinklers installed in areas with a finished ceiling shall have a factory finished 3-5/16” cover plate and shall be of an appropriate temperature classification for the hazard and offer up to 1” adjustment. Sprinklers shall be UL listed. Fast Response, Residential, Life Safety Flat Plate Concealed sprinklers shall be of the GL-RES/”INCH” Series; as manufactured by Globe Fire Sprinkler Corporation.

 