Our Products

:
S1 Standard Coverage

GL-SR | GL5661

Upright

Description

1/2" Upright Sprinkler, Standard Response | Series GL-SR Glass Bulb - 5.6 K-factor

Not all temperatures and configurations may carry all Listings and Approvals. See data sheet for conditions of specific Listings and Approvals.

temperature 135, 155, 175, 200, 286, 360
approvals cULus, FM, LPC, CE, NYC
SIN GL5661
wrench 325390

TECHNICAL DATA SHEET

STANDARD RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE)
GFS-100b_20180914CM (.pdf)
Download

FREQUENTLY ASKED QUESTIONS

The State of California's Safe Drinking Water and Toxic Enforcement Act of 1986 (Proposition 65) requires manufacturers and distributors to provide special warnings to consumers for products that contain certain chemicals. The list, which must be updated at least once a year, has grown to include approximately 900 chemicals. Examples of chemicals on the list: alcoholic beverages, lead, nickel, wood dust, and Diesel/gasoline engine exhaust. Globe Fire Sprinkler cares about our customers' safety and hopes the information provided in our Proposition 65 warnings assist with your purchasing decisions. The appropriate warning labels are required for all physical and internet sales.

REVIT Details

Sprinkler Globe Upright GL Commercial SR Imp (.rfa) Download
Sprinkler Globe Upright GL Commercial SR Metric (.rfa) Download

specifications

Glass Bulb - 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers. Standard Response, Standard Coverage: Where standard response, standard coverage upright or pendent sprinklers are specified they shall be of an all bronze frame construction with brass deflector. Sprinklers shall have a 5mm glass bulb thermally sensitive operating element, and rated for a working pressure of 175 psi.  Sprinklers installed in areas without a finished ceiling shall be of a bronze/brass finish and shall be of an appropriate temperature classification for the hazard. Sprinklers installed under a finished ceiling shall be a pendent style sprinkler with an adjustable recessed or extended escutcheon of the same specified finish. Sprinklers shall be UL listed or FM approved. Standard response, standard coverage sprinklers shall be of the Series GL-SR; as manufactured by Globe Fire Sprinkler Corporation.

 

 WARNING:  Cancer and Reproductive Harm – www.P65Warnings.ca.gov.

Associated Products