V5 Valve Accessories > Model FTV - PRV Flow Test Valve

Model FTV - PRV Flow Test Valve

Description

The Globe Fire Sprinkler Corporation PRV Flow Test Valve (FTV) is intended to be utilized downstream of pressure re­ducing control valves when present at multi-story building floor control assemblies. NFPA 25 requires PRV floor con­trol valves to undergo a full system demand flow test every 5 years. This test is to validate proper outlet pressure settings of the PRV floor control valve. The FTV may also be uti­lized to validate appropriate outlet pressure setting of a PRV during initial install. The FTV is available in 1-1/2” grooved inlet or 2-1/2” grooved inlet x 2-1/2” National Hose Thread outlet. A cap and chain is also included for the hose outlet. The Globe FTV eliminates the need to use multiple fittings and standard hose valves for testing of the PRV’s.

TECHNICAL DATA SHEET

GFV-130_20180508CM (.pdf) Download
GFV-132_20180508CM (.pdf) Download

FREQUENTLY ASKED QUESTIONS

The State of California's Safe Drinking Water and Toxic Enforcement Act of 1986 (Proposition 65) requires manufacturers and distributors to provide special warnings to consumers for products that contain certain chemicals. The list, which must be updated at least once a year, has grown to include approximately 900 chemicals. Examples of chemicals on the list: alcoholic beverages, lead, nickel, wood dust, and Diesel/gasoline engine exhaust. Globe Fire Sprinkler cares about our customers' safety and hopes the information provided in our Proposition 65 warnings assist with your purchasing decisions. The appropriate warning labels are required for all physical and internet sales.

specifications

PRV Flow Test Valve | Model FTV

 

Model FTV – PRV Flow Test Valve: Where a testing valve is required downstream of a pressure reducing valve in order to test the flow through the PRV; per the requirements of NFPA, a specifically manufactured valve for this purpose shall be used. Flow test valve shall have a grooved inlet and 2-1/2” Hose Thread outlet equipped with cap and chain. A single body flow test valve shall be of brass body construction, contain a Teflon seat, and be factory tested to 300 psi. PRV flow test valve shall be the Model FTV; as manufactured by Globe Fire Sprinkler Corporation.

 

  • PRV Flow Test Valve | Model FTV (1-1/2” Grooved Inlet x 2-1/2” Hose Thread Outlet)
  • PRV Flow Test Valve | Model FTV (2-1/2” Grooved Inlet x 2-1/2” Hose Thread Outlet)

 