Globe Model JG sprinkler guards are accessories designed to protect specific GL Series sprinklers where the potential of mechanical damage might be expected. In addition, GL Series water shields are used to protect the sprinkler’s thermosensitive element from the water spray discharge of higher elevation sprinklers. The use of the Model JGS guard and shield assembly with an appropriate upright sprinkler provides an approved “Intermediate Level” upright sprinkler assembly suitable for rack storage applications (See GFS450 for specific approvals). Likewise, the use of the GL Series water shield with an appropriate pendent sprinkler, provides a listed/approved “Intermediate Level” pendent sprinkler assembly suitable for rack storage applications (See GFS450 for specific listings/approvals). If a head guard is also desired for this pendent “Intermediate Level” sprinkler assembly, the JG head guard, in accordance with Table A, may be utilized in addition to the shield. The guards are available in red or chrome plated.
SPRINKLER GUARDS AND SHIELDS GUARD MODELS JG & JGS SHIELD MODEL GL SERIES
GFS-450_20190430CM (.pdf)
Download
|
Head Guards – Commercial and Intermediate Level Sprinklers:
Where there is a need for protecting automatic sprinklers from mechanical damage once installed in certain applications; they shall be installed within an automatic sprinkler head guard. Head guards shall be UL listed or FM approved for use with the sprinkler in which it is installed, to allow for proper discharge pattern of the automatic sprinkler upon activation. Head Guards shall be of the Model JG Series; as manufactured by Globe Fire Sprinkler Corporation.
· Head Guard (UL listed) | Model JG (Red) – Part Number #312253-1
· Head Guard (UL listed) | Model JG (Chrome) – Part Number #312253-C
· Head Guard (FM approved) | Model JG (Red) – Part Number #312253-1-B
· Head Guard (FM approved) | Model JG (Chrome) – Part Number #312253-C-
Water Shields – Commercial and Intermediate Level Sprinklers:
Where there is a need for protecting the automatic sprinklers thermosensitive element from the water spray discharge of higher elevation sprinklers; they shall be installed equipped with an automatic sprinkler water shield. Water shields shall be UL listed or FM approved for use with the sprinkler in which it is installed, to provide proper shielding from discharging elevated sprinklers. Water Shields shall be of the Model GL Series; as manufactured by Globe Fire Sprinkler Corporation.
· Water Shield | 1/2" NPT GL Series Shield – Part Number #325706
· Water Shield | 3/4" NPT GL Series Shield – Part Number #325707
Head Guards with Water Shield – Commercial and Intermediate Level Sprinklers:
Where there is a need for protecting automatic sprinklers from mechanical damage installed in certain applications and also a need for protecting the thermosensitive element from the water spray discharge of higher elevation sprinklers; they shall be installed within an automatic sprinkler head guard and water shield. Head guard and water shield assembles shall be UL listed or FM approved for use with the sprinkler in which it is installed, to allow for proper discharge pattern of the automatic sprinkler upon activation, while also protection the operating element for discharging elevated sprinklers. Combination Head Guards with Water Shield assemblies shall be of the Model JG Series; as manufactured by Globe Fire Sprinkler Corporation.
· Head Guard w/ Water Shield | Model JGS (Red) – Part Number #321406·
· Head Guard w/ Water Shield | Model JGS (Chrome) – Part Number #321407